描述
HAWK Industrial dial thermometers are designed to measure and indicate the temperature of a specific applications and conditions which are available in three actuation fills including liquid, mercury and gas. The dial thermometer can either be a directly local reading at the point of measurement or a remote reading by using a desired length of capillary tube. Model DSL, DSB, DSP and DSU are remote designs. Model DSE is a direct mounted type with adjust angle. Model DSR is a rigid thermometer for direct local mounting.
HAWK Supplies a wide selection of the available temperature ranges from -50°C to 650°C or equivalent in °F.
Typical Applications
- Petrochemical, oil and gas processing
- Medical and pharmaceutical industry
- Power generating stations
- Food and beverage processing
- Offshore oil platforms
- Pulp and paper mills
- Daily processing
- Waste water treatment
- Industrial OEM equipment
- Marine industry
- Military
Specifications
Operating
The temperature of the case should not be allowed to be exposed to continuous temperature in excess of 200°F (95°C). Stem and bulb should not be contact with sustained process temperature exceeding 50% over-ranger or 800°F (425°C).
Immersion
For getting the correct temperature readings, the stem of all models in all ranges must be immersed 2″ deep in liquid, and 4″ deep in gas except for 0/50°C (32/122°F) which require 3″ deep in liquid, and 4″ deep in gas.
Thermowell
Use of a thermowell is recommended when stem or bulb would be exposed to pressure, corrosive fluid or high velocity media. Use of a thermowell permits calibration check without interrupting or shutting the process. Thermowells are available in various styles, connections, materials and sizes.
Dial
3″(75mm), 3 1/2″(90mm), 4″(100mm), 4 1/2″(115mm) or 6″(150mm).
Case&Ring
Stainless steel 304 (SS316 – Option) and polished bayonet ring.
Mounting
DSL…back flange (surface, bottom).
DSB…back flange (surface, back).
DSP…front flange (flush panel, back).
DSU…U-clamp (flush panel, back).
DSR…rigid (stem, local).
DSE…adjust-angle (stem, local).
Window
Plain glass – Standard.
Tempered safety, Polycarbonate or Laminated safety glass – Optional.
Dial Face
Aluminum, white background with black graduations and figures.
Pointer
Anodized aluminum with black finish.
Scale
°C, °F (single or dual scale).
Accuracy
±1.0% of span (Grade A to ASME B40.3).
Capillary and Armor
304SS capillary and armor (316SS on request).
Connection Style
– Fixed Rigid Male/Female.
– Sliding Compression Male/Female.
– Union Rotatable Male/Nut Female.
– Swivel nut Male/Female Rotatable.
– Plain.
Connection Size
1/2″, 3/8″, 1/4″NPT standard, JIS, DIN, M14*1.0, M20*1.5 and others available.
Thermal Bulb
304 Stainless Steel, 10mm diameter – Standard, 3/8″ or others dia available.
Bulb Length
2 1/2″, 4″, 6″, 9″, 12″, 15″, 18″, 24″ standard lengths, available in stem lengths up to 72″ long.
Sensing Element
Bourdon Tube.
External Adjustment
Micro-Adjustable Pointer on request.
Weatherproof
NEMA 4/4X or IP65 enclosure.